US308MT Digital Flow Meter
US208MTUser Manual-V20240127The flow rate displayed is in litres per minute. The total flow displayed is in Litres. (By pressing SHIFT to shift the display)How to setProvide5-24V DCpower to light on,
- Model: US308MT
US208MTUser Manual-V20240127The flow rate displayed is in litres per minute. The total flow displayed is in Litres. (By pressing SHIFT to shift the display)How to setProvide5-24V DCpower to light on,
US308MT User Manual-V20240127
The flow rate displayed is in litres per minute. The total flow displayed is in Litres. (By pressing SHIFT to shift the display)
How to set
Provide 12V DC power to light on.
Open the back cover of the device
Press SET for 5 seconds to enter the menu or parameters
Then press SET to select the menu
Press + or - to increase or decrease the number, hold + or – to change the numbers quickly.
Parameters
1. 1.00500-K value, this setting value is 100 times the real K value
For example: the formula of the flow sensor is F=8Q, then real K=8, setting K is 800;
Range: 1-65535
Default value:500
2. 2.00500 – upper limit alarm value
=500L/Min means the alarm will go off when the flow rate is greater than the alarm value
Range: 1-65535
Default value:500
3. 3.001.00 – lower limit alarm value
=1.00 means the alarm will go off when the flow rate is lower than 1.0 litres/min
=0, function off
Range: 0.01-655.35
Default value:1.0
4. 4.00000: Total amount alarming value. When =0, Function off.
Range: 1-65535
Default value: 0, no display, no total volume alarm output.
5. 5.00000: Alarming time period. When =0, Function off.
Range: 1-65535
Default value: 0, always alarm after triggerred, when=3, alarm for 3 seconds and then off.
6. 6.00002: Decimal,
Range: 1-3
Default value: 2. the display number will show like 2.35(L/Min)
How to calibrate
Use K (constant) to calibrate the flow rate
Frequency = K x Flow rate
If K set on 10, and the flow rate is 4 lts/min
To calibrate to 8 lts/min, change K to 5 (10x4/8)